Skip to main content

BSEE Releases Technical Review of Seal Assembly and Cement Failures

The Bureau of Safety and Environmental Enforcement (BSEE) today released a technical review following an underground loss of well control that resulted in gas flow into a shallow sand reservoir. The technical review, entitled Evaluation of Seal Assembly & Cement Failures, was completed by the bureau's Quality Control-Failure Incident Team (QC-FIT) and submitted to BSEE Director Brian Salerno.

BSEE will continue to monitor information related to the performance of dual barrier systems, and will update this technical review as new information becomes available.

The QC-FIT technical review is available here.

Letter of Transmittal is available here.

BSEE Director Brian Salerno's response is available here.​​